A fault or an error has occurred
See the user guide for information on fault code 010-027
Solution :
Press 0 for 5 seconds and with continuous pressing 0 , press enter.
Password : 6789
Press Machine Status
Tools
Maintenance / Diagnosis
NVM Read/write …
744 – 220
Confirm / Changes
Change current value to new value i.e. 3 to 0
Save
Again Change current value to new value i.e. 0 to 0
Save (for confirm)
Then close (get out of the process)
Machine will reboot. Problem Solved !!!
See video ..... for detailed information
bjpagare